OmniCALL Control Panel Up to 32 Way, 1 x line card (OCCPS)

Control Panels

Brand
Baldwin Boxall
Model
OmniCALL Control Panel Up to 32 Way, 1 x line card (OCCPS)
Type
Control Panels
See all specifications

The Baldwin Boxall OmniCALL OCCPS is a compact master control panel for the OmniCALL Emergency Voice Communication (EVC) system. Featuring a patent-pending design that supports both loop and radial cabling on the same network, it manages up to 32 outstation addresses per loop card across disabled refuge units, fire telephones, steward handsets, and emergency toilet alarms.

Hybrid Loop & Radial ArchitectureSupports flexible loop-wired and radial-wired outstation connections on the same panel using standard 2-core cable, enabling versatile, cost-effective field installation.32-
Way Outstation CapacityPre-fitted with 1 loop card to manage up to 32 addressable remote outstations per loop, fully addressable via the master station.
Universal Remote IntegrationCompatible with all five OmniCALL outstation styles (disabled refuge, fire telephones, combined units, advanced refuge, and assistance call points) without requiring unique outstation hardware for loop vs. radial lines.
Direct Toilet Alarm IntegrationConnects Emergency Assistance Toilet Alarms directly to outstations, assigning each assistance call point its own unique, monitored system address.BS 5839-9:2021 & BS 8893:2024
ComplianceFully engineered to fulfill current UK codes of practice for emergency voice communications and disabled refuge installations (along with BS 8300:2018 for toilet alarms).
Centralized Power & Fault MonitoringContinuously monitors all loop and radial field wiring for open or short circuits while providing system-wide battery backup and fault diagnostic reporting.
View all

Baldwin Boxall

Console Black 4 Way (C2CB4)

Control Panels

  • Scalable 4-to-256 Way System: Begins as a compact 4-line unit, expands locally to 16 lines
  • Uninterrupted Power Protection: Built-in battery backup keeps the entire system fully operational
  • Clear Control & Accessibility: Combines an intuitive rotary encoder with a high-contrast LCD screen

Baldwin Boxall

4-Way Expansion Kit (C2CEK4)

Control Panels

  • Way Outstation Line Capacity: Supplied as a 4-way base panel
  • Network Expansion & Scalability: Supports up to 15 Network Expansion Panels (NEPs)
  • Network Ring Topology: Interconnects control panels

Baldwin Boxall

Fire Panel/Ethernet Module (C2CFPE)

Control Panels

  • Ethernet & PC Configuration: Features an onboard Ethernet port to allow remote programming
  • Flexible Fire Panel Inputs: Supports both volt-free contact inputs
  • Common Fault Relay Outputs: Provides dedicated fault contacts to relay CARE2 system status

Baldwin Boxall

Network Card (C2CN)

Control Panels

  • Panel Network Interconnect: Enables ring networking for up to 16 panels
  • Included Modular Kit: Supplied complete with the C2CN PCB card
  • BVOCCA & Delayed Call Control: Includes jumper configuration settings

Baldwin Boxall

Network Expansion Panel Black 4 Way (C2CBNEP)

Control Panels

  • Fire Alarm System Interlock: Links directly to the FACP to manage disabled refuge outstations
  • Selective Outstation Operation: While disabled refuge outstations are held in standby
  • External Delayed Call Output: Features an onboard potentiometer (VR1) and jumper configuration pins

Baldwin Boxall

Fire Telephone Lock door Red (C2FTRL)

Devices

  • BS 5839-9 Type A Life Safety: Fully certified Type A emergency outstation designed
  • Powered Operation: Powered directly over a 2-core radial connection
  • Distance Radial Cabling: Supports cable distances up to 500 meters between the control panel

Baldwin Boxall

Fire Telephone Push door Red (C2FTRP)

Devices

  • Safety Compliance: Certified Type A outstation engineered to support emergency personnel
  • Duplex Speech & Conference Capability: Enables simultaneous two-way audio back to the central console
  • Hearing Aid Accessible Handset: Fitted with a high-durability red handset

Baldwin Boxall

3 Part Disable Toilet Alarm Kit -White (DTAKIT)

Devices

  • Part Alarm Package: Supplied with a ceiling pull cord unit, a reset point switch
  • Universal EVC System Compatibility: Connects directly into CARE2, OmniCare, and OmniCarePLUS EVC networks
  • Interactive Caller Reassurance: Accepting an active call at the master control panel sends visual

Baldwin Boxall

4 Way Toilet Alarm Control Panel White (DTA4)

Control Panels

  • Chain Expansion: Directly controls up to 4 assistance alarm zones
  • Interactive Call Acknowledge & Reassurance: Pressing a zone's call accept button on the panel alters the visual
  • Continuous Line & Fault Surveillance: Continuously monitors field wiring for open or short circuit faults

Baldwin Boxall

Call Button White (DTACB)

Devices

  • Safety Compliance: Designed to fulfill UK building accessibility standards
  • Backed: Powered directly from the host EVC panel or DTA4 controller line
  • Way Call Acknowledge & Reassurance: Accepting an active call at the control panel changes the visual

Baldwin Boxall

Call Button & Reset Point White (DTACBRP)

Devices

  • Combined Call & Reset Functionality: Integrates a prominent emergency call push-button
  • Interactive Caller Reassurance: Features internal LED indicators
  • Powered Operation: Powered directly over the system loop or radial line (16–20 V DC)