The Baldwin Boxall OmniCALL OCAFRP is a red Type A Fire Telephone Outstation featuring a push-latch door mechanism engineered for life-safety voice communication between firefighters, evacuation marshals, and building management. Designed for OmniCALL's hybrid loop or radial network architecture, opening the door automatically initiates a call to the master station, providing full-duplex speech, 4-way multi-party conferencing, an internal loudspeaker, and high-visibility luminescent labeling.

FeaturesBS 5839-9:2021 & BS 8893:2024
ComplianceCertified Type A outstation built to meet UK codes of practice for emergency service communications during building evacuations.
Hybrid Loop or Radial CablingConnects to OmniCALL master panels via non-polarity-dependent 2-core fire-rated cabling across loop or radial topologies, self-powered directly from the line (15–36 V DC, 30 mA @ 24 V).Automatic Push-
Door Call InitiationOpening the push-catch door instantly triggers an emergency call alert at the master station.Full-Duplex Speech & 4-
Way ConferenceDelivers clear two-way simultaneous voice communication with operator-managed conference calling across up to 4 concurrent Type A or Type C outstations plus the master station.
Accessibility & Visibility FeaturesFitted with a red handset featuring a built-in T-coil earpiece for hearing aid users, photoluminescent labelling for dark or smoky environments, and a local call indication speaker.
Compact Physical Footprint & MountingMeasures 130 mm (W) × 350 mm (H) × 80 mm (D) in RAL 3020 red finish; surface mounts as standard or flush mounts using bezel OCAFR-BZ (cutout: 138 mm × 358 mm). Recommended installation height is 1300–1400 mm to center.
View all

Baldwin Boxall

Console Black 4 Way (C2CB4)

Control Panels

  • Scalable 4-to-256 Way System: Begins as a compact 4-line unit, expands locally to 16 lines
  • Uninterrupted Power Protection: Built-in battery backup keeps the entire system fully operational
  • Clear Control & Accessibility: Combines an intuitive rotary encoder with a high-contrast LCD screen

Baldwin Boxall

4-Way Expansion Kit (C2CEK4)

Control Panels

  • Way Outstation Line Capacity: Supplied as a 4-way base panel
  • Network Expansion & Scalability: Supports up to 15 Network Expansion Panels (NEPs)
  • Network Ring Topology: Interconnects control panels

Baldwin Boxall

Fire Panel/Ethernet Module (C2CFPE)

Control Panels

  • Ethernet & PC Configuration: Features an onboard Ethernet port to allow remote programming
  • Flexible Fire Panel Inputs: Supports both volt-free contact inputs
  • Common Fault Relay Outputs: Provides dedicated fault contacts to relay CARE2 system status

Baldwin Boxall

Network Card (C2CN)

Control Panels

  • Panel Network Interconnect: Enables ring networking for up to 16 panels
  • Included Modular Kit: Supplied complete with the C2CN PCB card
  • BVOCCA & Delayed Call Control: Includes jumper configuration settings

Baldwin Boxall

Network Expansion Panel Black 4 Way (C2CBNEP)

Control Panels

  • Fire Alarm System Interlock: Links directly to the FACP to manage disabled refuge outstations
  • Selective Outstation Operation: While disabled refuge outstations are held in standby
  • External Delayed Call Output: Features an onboard potentiometer (VR1) and jumper configuration pins

Baldwin Boxall

Fire Telephone Lock door Red (C2FTRL)

Devices

  • BS 5839-9 Type A Life Safety: Fully certified Type A emergency outstation designed
  • Powered Operation: Powered directly over a 2-core radial connection
  • Distance Radial Cabling: Supports cable distances up to 500 meters between the control panel

Baldwin Boxall

Fire Telephone Push door Red (C2FTRP)

Devices

  • Safety Compliance: Certified Type A outstation engineered to support emergency personnel
  • Duplex Speech & Conference Capability: Enables simultaneous two-way audio back to the central console
  • Hearing Aid Accessible Handset: Fitted with a high-durability red handset

Baldwin Boxall

3 Part Disable Toilet Alarm Kit -White (DTAKIT)

Devices

  • Part Alarm Package: Supplied with a ceiling pull cord unit, a reset point switch
  • Universal EVC System Compatibility: Connects directly into CARE2, OmniCare, and OmniCarePLUS EVC networks
  • Interactive Caller Reassurance: Accepting an active call at the master control panel sends visual

Baldwin Boxall

4 Way Toilet Alarm Control Panel White (DTA4)

Control Panels

  • Chain Expansion: Directly controls up to 4 assistance alarm zones
  • Interactive Call Acknowledge & Reassurance: Pressing a zone's call accept button on the panel alters the visual
  • Continuous Line & Fault Surveillance: Continuously monitors field wiring for open or short circuit faults

Baldwin Boxall

Call Button White (DTACB)

Devices

  • Safety Compliance: Designed to fulfill UK building accessibility standards
  • Backed: Powered directly from the host EVC panel or DTA4 controller line
  • Way Call Acknowledge & Reassurance: Accepting an active call at the control panel changes the visual

Baldwin Boxall

Call Button & Reset Point White (DTACBRP)

Devices

  • Combined Call & Reset Functionality: Integrates a prominent emergency call push-button
  • Interactive Caller Reassurance: Features internal LED indicators
  • Powered Operation: Powered directly over the system loop or radial line (16–20 V DC)